Description Datasheet
 

Outback Power EnergyCell 48-FLA-525 > 445 Amp Hour 48 Volt Flooded Battery System

Manufacturer Part Number: EnergyCell 48-FLA-525

OutBack Powers EnergyCell 48-FLA-525 battery system includes eight Outback Power EnergyCell 525FLA Flooded Batteries, Polyproplylene Enclosure, Watering System, interconnects and hardware.

OutBack Powers EnergyCell 48-FLA-525 battery system is designed for residential or light-commercial off-grid renewable energy power demands. Optimized to work seamlessly with OutBack power conversion equipment, these batteries are a perfect addition to the OutBack single-brand system solution. Built for rugged, deep cycle cell construction, these batteries deliver superior performance and longevity.

Specifications

EnergyCell 48-FLA-525
Capacity 8 EnergyCell 525FLA Batteries
Nominal Voltage 48VDC
Amp Hour Capacity to 1.75 Volts Per Cell at 20 C (24 hour Rate) 445
Cycle Life (50% DOD, 1.75VPC) 1550
Shipping Method Freight


EnergyCell 525FLA
Cells Per Unit: 3
Nominal Voltage 6VDC
Amp Hour Capacity to 1.75 Volts Per Cell at 20 C (24 hour Rate) 445
Cycle Life (50% DOD, 1.75VPC) 1550
Absorb Voltage (25 C) 7.26VDC
Absorb Time 2 hours
Float Voltage (25 C) 6.75VDC
Float Time = absorb time
Equalize Charge Frequency Equalize charge every 30 days, systems that are regularly discharged below 50% of stored capacity should be equalized every 14 days.
Re-Bulk Voltage 12VDC/ 24VDC/ 48VDC
Re-Float Voltage 12.5VDC/ 25VDC/ 50VDC
Maximim Charge Current (Per Battery) 100A
Operating Temperature Range
(w/ Temperature Compensation)
-40 to 120F (-4 to 49C)
Optimal Operating Temperature Range -40 to 80F (4 to 27C)
Temp-Comp Factor (Charging) 3mV per C per cell
Self-Discharge Time Fully charged batteries that are stored at a temperature of 80F (27C) will self discharge at a rate of 3.5% per week.
Terminal Type Standard type with stainless steel
Terminal Hardware Initial Torque Stainless thread, 100 to 120in-lbs (11 to 14Nm)
Weight 112 lbs / 55.3 kg
Dimensions
(H x D x W)
16.13" H x 7.19" D x 12.38" W
Warranty 2 years full replacement
Equalize Voltage 7.74VDC
Specific Gravity Full charge specific gravity (100% state of charge): 1.125
Vent Cap Bayonet
PROeye Electrolyte Level Indicator No

Features

  • Batteries designed for residential, light-commercial grid-tied backup or off-grid renewable energy power demands
  • 1,500 cycles of 50% DOD
  • Pure lead extends the life of the battery versus traditional VLRA batteries and allows the increased float capability and maximizes runtime for backup applications.
  • Easy to install and maintain
  • PLR technology means 99% gas recombination efficient, no periodic watering of cells, no re-torquing of terminal connections, and no equalization charge under standard operating conditions
  • Optimized to work seamlessly with OutBack power conversion equipment

Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Deep Cycle Batteries > Outback Power Batteries > Outback EnergyCell FLA (Flooded Lead Acid)
Deep Cycle Batteries > Flooded Batteries
Manufacturers > Outback Power
200 +
6 VDC
Deep Cycle Batteries > Outback Power Batteries
Deep Cycle Batteries
Manufacturers