Request a Quote!


Customer Reviews
"Ecodirect.com is the best! They are such a pleasure to work with! Great brands at the best prices. Special thanks to RenĂŠe who always answered my questions on the spot, and giving thoughtful advice." Serge (Tahiti, French Polynesia)
"The experience I had with my purchase was very good. The items I ordered arrived when I expected & were packaged well. My overall purchasing experience was very positive."

- Thank you,
Marlene
"I recently found EcoDirect & have been extremely happy with their service. They have had all the PV modules, inverters, optimizers and accessories I needed. They provide excellent customer service & turn orders around very quickly. I have switched to EcoDirect for all my parts & materials orders. Highly recommended."

- Zeno
"I wanted to let you know I am very pleased with the service you gave & the quality & condition of the solar panels I received from EcoDirect. I will purchase more items in the future from EcoDirect and will be sure to tell others about your fine operation."

Thanks,
Maurice
"Thanks EcoDirect! My solar system is up and running; waiting for City and San Diego Gas & Electric inspections this week; so far so good!"

- J.L.,
Oceanside, CA
"I enjoyed ordering what I needed. It was simple and fast, no issues what so ever. If I need something else and its at a good price, I will defiantly order from here again. Also the shipping is at a good price."

- Simon
My shipment arrived on time, as predicted. Very, very good performance by EcoDirect. What more could you ask for from an online material supplier? Looks like the quantity from Quick Mount is spot on & the rails were bundled safely. EcoDirect will be my recommended source to my friends & neighbors for solar.
- Thank you, Jim Lake
Escondido, CA
"Over the past couple of years, I have purchased several items from Ecodirect and I have always been happy with their customer service and prompt delivery of products."

- Chris
"I am very satisfied, everything was as expected."

- Anon

  Home >

Bogart Engineering MKB-500-50 > 500A / 50mV Shunt
Bogart Engineering - 500A / 50mV Shunt - MKB-500-50
Bogart Engineering 500A / 50mV Shunt


 
Alternative Views:


Our Price: $37.76

Product Code: BOGART-MKB-500-50
Qty:

Description
 

Bogart Engineering MKB-500-50 > 500A / 50mV Shunt

How a shunt works

A shunt is necessary in order to measure amps and amp-hours with the TriMetric battery monitor. A shunt is an accurate, very low resistance resistor which is placed "in line" with the wire carrying the current to be measured. With the TriMetric, it is usually placed in the negative wire from the battery bank, such that all the current going into the battery (charging) or out (discharging) must pass through it. Connected in this way it will be set up to monitor "net" amp-hours in and out of the battery. (It also could be placed in series with the negative wire coming from a solar array--or other charging source--in which case it would measure only the solar array current, if that were desired--to show total solar "amp hours" production.) The shunt needs to be placed near the batteries; since these wires carry very high currents the wires from the batteries must be kept short to minimize electrical losses.

Shunt resistance

When current flows through the shunt, a small voltage is developed across the shunt which is proportional to the current flow. The TriMetric battery monitor accurately measures this very low voltage and converts it to the "amps" reading on the meter. The resistance, which is the ratio between the voltage across the shunt and the current flowing through it, is a constant for any particular shunt--and is one of its important parameters. For most substances, resistance is usually described in "ohms", however for some reason shunts are described by the voltage drop that occurs with a certain current: for example: "50 millivolts at 500 amperes." However the meter only cares about the ratio-which is the resistance--so a 500Amp/50 millivolt shunt is equivalent, from the TriMetric's view, to a 250Amp/25 millivolt shunt. They both have a resistance of 0.1 milliohm, or one ten thousandth of an ohm.

Setting up the TriMetric for correct shunt

The TriMetric is designed to use either a 500 Amp/50 millivolt (0.1 milliohm) or 100 Amp/100 millivolt (1.0 milliohm) shunt. The latter shunt delivers 10 times the voltage for a given current flow through the shunt, so the meter can show an extra digit of current resolution (down to 0.01 amp) compared with the 500 Amp/50 millivolt shunt, which displays a minimum current of 0.1 amp. To make the TriMetric read "amps" and "amp-hours" correctly, you must tell the TriMetric which shunt is being used. This is done by programming either an "L" (low) or "H" (high) in one of the program modes. ("L" for the 100A/100 mV shunt, and "H" for the 500 A/50 mV shunt.) For how to do this refer to TriMetric instructions under "How to set efficiency factor and shunt type".