Pytes Energy > 100.35 kWh High Voltage Outdoor Commercial Battery System compatible w/ Sol-Ark 30k & Solis S6-EH3P Inverters | IP55 Outdoor Commercial & Industrial Enclosure | C&I
"HV48300 (7S2P) – 200.76 kWh / 358.4 V / 560 Ah / 2*140 A;
Certificates: UL 9540, UL 9540A, UL 1973;
Outdoor-rated IP55 Cabinet w/ HVAC
Safety Features: Aerosol Fire Suppression, Explosion Relief Plate, Hazardous Gas Detection & Ventilation, Fire Hose Connection"
|
Model
|
HV48300SE MAX
|
|
Series
|
HV48300
|
|
Compatible with
|
Sol-Ark 30K
As well as Solis Inverters:
S6-EH3P 30k
(Inverter Not Included)
|
|
Manufacturer
|
Pytes Energy
|
|
Components Included:
|
|
Pytes Energy Battery Module Unit - HV48100SE BMU (7S2P)
|
Qnty. 14
|
|
Pytes Energy Battery Control - Unit HV48100SE BCU
|
Qnty. 2
|
|
Pytes Energy HV48100SE Cabinet
|
Qnty. 1
|
Product Specifications
|
Battery Module
|
|
Battery Chemistry
|
Lithium Iron Phosphate (LFP)
|
|
Battery Module Nominal Voltage
|
5.12 kWh
|
|
Battery Module Operating Voltage
|
44.8~57. 6 V
|
|
Battery Module Nominal Capacity
|
314 Ah
|
|
Battery Module Energy
|
16.076 kWh
|
|
Weight
|
262 ± 11 lb / 119 ± 5 kg
|
|
System
|
|
Battery Module Internal Configuration
|
7S2P
|
|
Nominal Energy
|
225.075 kWh
|
|
Nominal Output Power
|
112.53 kW
|
|
Operating Voltage
|
313.6 ~ 403.2 V
|
|
Recommended Charge / Discharge Current
|
157 A*2
|
|
Peak Charge / Discharge Current
|
205 A*2
|
|
General
|
|
Dimensions (W x D x H)
|
69" x 57" x 93"
(1750 x 1450 x 2350 mm)
|
|
Approximate weight
|
5388 lbs/ 2444 kg
|
|
Ingress Protection Rating
|
IP55
|
|
Cycle Life
|
6000 Cycles
|
|
Warranty
|
Battery system: 3 Years
Battery module: 10 Years
|
|
Environmental
|
|
Operating Temperature
|
Charging: 32 °F ~ 131 °F (0 °C~55 °C)
Discharging: -4 °F ~ 131 °F (-20 °C~55 °C)
|
|
Operating Altitude
|
≤ 6561.68 ft
(2000 m)
|
|
Relative Humidity
|
5% ~ 95 % non-condensing
|
|
Fire Suppression System
|
|
Level 1: Detection & Ventilation
|
Hazardous gas detection activates ventilation system
|
|
Level 2: Aerosol Suppression
|
Heat and smoke detection activates aerosol fire suppression system
|
|
Level 3: Pressure Relief
|
The explosion relief valve opens automatically if internal pressure exceeds safe limits
|
|
Level 4: Fire Hose Connection Port
|
Equipped with a fire hose connection port for firefighter hose attachment
|
|
HVAC
|
|
Max. Cooling Capacity
|
5000 W (L35)
|
|
Max. Heating Capacity
|
2500 W
|
|
Ingress Protection Rating
|
IP55
|
|
Compliance
|
|
Certifications
|
UL 9540 Ed.3 (2023), UL 9540A (2025), UL 1973, UN 38.3
|
|
Code Compliance
|
NFPA 68 / 69 / 855
|
|
Listings
|
CEC, SGIP, OGPe
|
Pytes HV48100 SE Battery System | Key Features and Benefits
Safe
-
Tier 1 automotive-grade LFP cells
-
BMS multi-level monitoring and protection
- Multi-layer active fire suppression system
All-Weather
- Built-in module-level fans and forced-air cooling system (HVAC) ensure efficient thermal management and reliable operation in high-temperature environments
- IP55 rating for indoor and outdoor installation
Scalable
- Scale seamlessly to MWh-level capacity with our modular battery system — ideal for commercial and industrial-scale applications
Smart
- Remote monitoring with PYTES Battery Cloud
Flexible
- Available in 3 standard configurations, plus with the flexibility to accommodate different inverter voltage input ranges
-
Universal mounting structure accommodates various inverter models
Documentation
|
Data Sheet
|
Pytest Energy HV48300SE-MAX Outdoor Commercial & Industrial Battery System | C&I
|
|
|
 |
 |
 |
 |
|
 |


|