Request a Quote!


  Home > Power Inverters > OutBack Power Inverters > Outback Power FLEXpower Series >

OutBack Power FP4 FXR3048A-01 > 12kW FLEXpower Four Fully Pre-Wired Quad Inverter System - UL 1741 SA Compliant

OutBack Power FP4 FXR3048A-01 > FLEXpower Four 12kW Fully Pre-Wired Quad Inverter System - UL 1741 SA Compliant


 
Our Price: $18,715.00


Availability: This item may have a lead time of 14 - 16 weeks.
Product Code: OUTBACK-FP4-FXR3048A-01

OutBack Inverter Lead Time Approval

Click here to acknowledge that APPROVE the lead time of 14-16 weeks for OutBack Power FLEXpower Inverter.

Qty:
Description Videos Datasheet
 

OutBack Power > FLEXpower Four 12kW Fully Pre-Wired Quad Inverter System - UL 1741 SA Compliant

Fully Pre-Wired Quad Inverter System - 120/240 VAC, 60Hz
NOTE: All FLEXpower systems will once again be provided with MATE3s.

UL 1741 SA, CA Rule 21, and HECO Rule 14H Compliant

Ships in approximately 3-4 Weeks

Model FP4-FXR3048A-01
Series FlexPower Four
Manufacturer Outback Power
Application 120/240 VAC / 60 Hz
Inverter Model FX3048A-01 (4x)
FW-X240 Yes
Bypass 240 VAC Bypass
Charge Controller FLEXmax 80 (4x)
Inverter Model 175A
PV OCPD
80A
Dimensions L 58.425" x H 46" x D 13"
Weight 500 lbs
Shipping Method Freight

Features

  • Factory tested, pre-wired and pre-configured systems
  • Fast installation—just hang on the wall with the bracket (included) and make connections
  • Off-grid and grid-tied functionality in one flexible system
  • Powerful system in a compact, space-saving footprint
  • Field-upgradable software
  • Ample AC and DC breaker provisions
  • GridZero technology effectively lets users “zero out” the utility grid if enough renewables are present, reducing or even eliminating grid dependence
  • Advanced Battery Charging (ABC) supports a wide range of battery technologies including lithium-ion
  • All components carry necessary ETL certifications

Product Description

OutBack’s pre-assembled and pre-wired FLEXpower system (FP4 FXR3048A-01) is now equipped with the updated FXR Series Grid/Hybrid inverter/chargers. This means that the most advanced Grid/Hybrid inverter features are now available on the industry’s most trusted and proven systems platform, for unmatched flexibility and value.

  • 2 models available for 120/240VAC applications, ranging from 12kW to 14.4kW.
  • 50Hz/60Hz selectable for regional diversity.
  • Programmable for seven different modes including GridZero ,which blends utility power and stored renewable energy, minimizing grid dependence; also Support Mode for seamless generator integration.
  • Advanced Battery Charging (ABC) with expanded charging voltages and time parameters accommodates charging profiles of new and emerging storage technologies including Lithium Ion, and Aqueous types.
  • Field-upgradability eliminates system down-time for critical updates.
  • Remote system control and monitoring available through any internet-enabled device with OPTICS RE.

The FLEXpower FOUR is ideal for split-phase applications with large power requirements such as larger residential, commercial or village power systems, with all necessary components integrated into a compact hang-on-the-wall system with a minimal footprint.

The Future of Grid-Tie Stability

As more PV is installed on electrical grids, grid operators need flexible tools to help ensure stability and reliability. Areas with the highest PV penetration rates (Hawaii and California) will soon require grid interconnected systems to have "Grid Support" functions.

OutBack Power is certifying the Radian Series inverter/chargers (along with the FXR Series in the near future) under the new UL 1741 SA test standard to demonstrate compliance with these new requirements from CA Rule 21 and HECO Rule 14H.

What is UL 1741 SA and When Does it Take Effect?

UL 1741 SA is the new safety test standard certifying products which meet the rigorous requirements needed to ensure safe and reliable operation in support of grid modernization efforts. Grid support or "smart inverter" functionality will be required by Hawaii and California beginning September 8, 2017.

Although Hawaii and California are the first states to require grid support functions, expected updates to the IEEE 1547 interconnection standard will make these functions mandatory throughout most of North America within two to three years.

Is Grid Support Important?

As the PV market has grown, the industry has seen increasing grid instability, voltage rise limits, and a lack of standard communication protocol. With added grid support functions, the Radian Series inverter/chargers are being listed to UL 1741 SA, solving key grid integration challenges. UL 1741 SA compliance is planned for OutBack's FXR A Series in the near future.

With the advent of grid support technology, UL 1741 SA compliant models can regulate voltage and power, and they can prevent loss of power generation due to grid disturbances.


Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Power Inverters > OutBack Power Inverters > Outback Power FLEXpower Series
Power Inverters > Pre-Wired Inverters
Manufacturers > Outback Power
Power Inverters
Power Inverters > OutBack Power Inverters
Manufacturers