ProHarvest by OutBack > ProHarvest 208V Commercial String Inverter
3-phase 208V String Inverter for Commercial applications
Designed for reliability, the ProHarvest 208V String Inverter (PRO208-5k75) is an easy to install, modular system optimized specifically for commercial rooftop ungrounded solar array applications. Unlike other string inverters, each string is individually monitored and managed by the inverter. Inverter AC cables must be ordered separately.
Specifications
Model
|
PRO208-5k75
|
Series
|
ProHarvest
|
Manufacturer
|
Outback Power
|
Mechanical
Type
|
Commercial three-phase 480V String Inverter
|
Dimensions (W x H x D)
|
18.75" x 13.125" x 3"
|
Weight
|
24 lbs
|
Operating Temperature Range
|
-40° C to 65° C
|
Enclosure
|
NEMA6, IP67, Outdoor/Rooftop
|
Cooling
|
Natural convection, no fan
|
Communication
|
Powerline
|
Certifications
|
Listed to UL1741/IEEE 1547 (utility interactive) CSA C22.2 No. 107.1, FCC Part 15, meets the requirements of NEC 690.11
|
Warranty
|
10-year, optionally extendable
|
Shipping Method
|
Ground
|
Input (DC)
Max. Open Circuit Voltage
(per string)
|
1000 VDC
|
Full Power MPPT Range
(per string)
|
325 to 525 VDC
|
PV Start Voltage
|
200 VDC
|
DC Allowable Stacking Ratio
(total, 2 inputs combined)
|
Must not exceed 8.9 under any circumstances
|
DC Maximum Input
|
Current (per DC input): 10A
Short circuit current: 30A
|
DC Disconnect Means
|
DC connector has been evaluated and approved for use as the load-break disconnect required by the NEC (NEC section 690.17, allowed by the exception of meeting requirements specified in 690.33)
|
Output (AC)
AC Maximum
|
Continuous total output power (to 45°C): 5.75kW
Continuous output current (per phase): 16A Output overcurrent protection: 60A
|
AC Derate (40-65°C)
|
-102W per °C
|
AC Nominal Output Current (per phase
|
16 A
|
AC Three-Phase System Compatibility
|
208V Wye, three phases, neutral and ground
|
AC Voltage Range
(limits adjustable)
|
Phase to Phase
Minimum: 183V
Nominal: 208V
Maximum: 229V
Phase to Neutral
Minimum: 106V
Nominal: 120V
Maximum: 132V
|
AC Output Frequency Range
(limits adjustable)
|
Minimum: 59.3Hz Nominal: 60Hz Maximum: 60.5Hz
|
Power Factor
|
≥0.98
|
AC Upper Trip Limit
|
Frequency
Default (±1Hz): 59.3Hz
Adjustment (±1Hz): 57 to 59.3Hz
Clearing Time Default (±2 Cycles): 0.16s
Clearing Time Adjustment (±2 Cycles): 0.16 to 300s
Voltage (Phase to Neutral)
Default (±2%): 106V
Adjustment (±2%): 85 to 106V
Clearing Time Default (±2 Cycles): 2s
Clearing Time Adjustment (±2 Cycles): 1 to 20s
|
AC Lower Trip Limit
|
Frequency
Default (±1Hz): 60.5Hz
Adjustment (±1Hz): 60.5 to 62.0Hz
Clearing Time Default (±2 Cycles): 0.16s
Clearing Time Adjustment (±2 Cycles): 0.16 to 300s
Voltage (Phase to Neutral)
Default (±2%): 132V
Adjustment (±2%): 132 to 144V
Clearing Time Default (±2 Cycles): 1s
Clearing Time Adjustment (±2 Cycles): 1 to 20s
|
AC Reconnect Delay
|
Default: 5 min
Adjustment: 1 second to 10 min
|
AC Synchronization In-Rush Current
|
0 A
|
Maximum Output Fault Current and Duration
|
16 A, <0.5ms
|
AC Minimum Wire Gauge
(for grid connection)
|
12 AWG
|
AC Disconnect Means
|
The AC connector has been evaluated and approved for use as the load-break disconnect required by the NEC (NEC section 690.17, allowed by the exception of meeting requirements specified in 690.33)
|
Documentation
Features
- Rugged 3-phase 208V plug & play system
- Small and light (hand holdable, 24lb.)
- Non-isolated inverter for use with ungrounded DC systems
- 98% peak, 97% CEC efficiency
- 200-850V MPP voltage range for 600V and 1,000V systems
- 5.75kW, full power MPP voltage 325-525V
- Two DC string inputs with independent monitoring and MPPT management
- Waterproof NEMA6, silent convection cooling
- Wide temperature range (-40 to 65°C)
- Compliant with NEC 690.11 arc detection
Applications
- Rooftop commercial: usable where other solutions just won’t work
such as coastal, desert and high altitude locations
- Car ports, parking and shade structures: can be mounted at any
orientation, under modules, on racking without extra strengthening
(clear of risk of liability from vandalism)
|
|
|
|
|
|
|