Midnite Solar Nottagutter Breaker & Wiring Box
Manufacturer Part Number: Nottagutter-4
Dual 60 amp and four 60 amp single breakers.
Competing systems mount the inverters too close together. Notice the physical separation between inverters on the Nottagutter that offers better cooling and improved reliability. Higher charger rates are also achieved due to improved cooling. The Nottagutter also takes up less wall space.
Features
-
Positive DC battery/inverter busbar with five 5/16” diameter studs locatable on either side of enclosure
-
Negative DC inverter busbar with four 5/16” diameter studs mounted on one half of 500 amp shunt
-
Negative DC battery connection on side of 500 amp shunt. Shunt may be located on either side
-
15 position terminal busbars for leg 1 & 2 AC IN, leg 1 & 2 AC OUT, Neutral and Ground.
-
Mounting embosses for AC leg 3 in and out or other insulated circuits (MNSBB)
-
60 amp 277VAC 2 pole bypass breaker standard
-
60 amp inverter AC output breakers (specify 2,4,6 or 8)
-
Center din rail mounts up to twelve single pole or six 2 pole breakers in any combination
-
Bypass slider configurable for up to four single pole or two 2 pole breakers on one side and 8 single pole breakers on the other side. The eight breakers may be AC output and AC input together. The eight breakers may also be four 2 pole breakers.
-
Four Ultralite E-Panels can mount to each Nottagutter for OutBack, Magnum and Apollo inverters.
-
Up to two Sunny Island inverters accommodated easily
-
175 or 250 amp inverter breakers may be installed in each end of the enclosure
-
Right and Left hand charge control brackets may be installed in each end of the enclosure
Six position din rail included that can mount in one of the DC positive busbar locations
-
Knockouts for single charge controller on the side in the middle of enclosure
-
Knockouts on top and bottom surfaces to match up with Ultralite E-Panels and battery conduit connections
Specifications
Description |
Install up to four UltraLite E-Panels with each Nottagutter. The Nottagutter accepts two E-Panels on top and two E-Panels bottom or on the sides as shown to the right. Dual 60 amp bypass and two 60 amp single breakers. |
Box Size |
40” x 16” x 6”
|
Weight |
20 Lb/s |
Detailed Description
The ends are designed to accept inverters, charge controllers or inverter battery breakers. Features include massive DC+ and DC- busbars to accommodate up to four inverters and auxiliary DC circuits. Terminal busbars include 120/240V AC input, AC output, Neutral and ground busbars. Additional space allows for three phase busbars. 60 amp AC Bypass is standard. The -2 version comes with two 50 amp output breakers. -4 comes with four 50 amp output breakers etc. Charge controllers mount on the top middle or on each end with optional charge control brackets.