Request a Quote!


  Home >

SolarEdge OP300-MV-AH4SM-2NA > 300 Watt Power Optimizer > Helios/MC4

SolarEdge OP300-MV-AH4SM-2NA - 300 Watt Power Optimizer > Helios/MC4


 

Stock Status:(Out of Stock)

Availability: This item is no longer available.
Product Code: SOLAREDGE-OP300-MV-AH4SM-2NA
 

Description Videos Datasheet
 

SolarEdge 300 Watt Power Optimizer

IN: Helios H4
OUT: MC4
Manufacturer Part Number: OP300-MV-AH4SM-2NA

SolarEdge power optimizers offer a superior approach to maximizing the throughput of photovoltaic systems using module embedded electronics. With superior efficiency (99.5%) even in mismatched and unshaded conditions and a flexible system design for maximum space utilization, these optimizers can offer a 25% increase in power output over a traditional central inverter.

Features

  • Module level MPPT - optimizes each module independently
  • Dynamically tracks the global maximum operating point for both modules and PV inverter
  • Module-level monitoring for automatic module and string level fault detection allowing easy maintenance
  • Electric arc detection - reduces fire hazards
  • Unprecedented installer and firefighter safety mode - safe module voltage when inverter is disconnected or off
  • Connection of one or more modules to each power optimizer
  • Lower installation costs with faster design, less wiring, DC disconnects and fuses
  • Easy and flexible installation – use the same installation methods as exist today
  • Allows parallel uneven length strings and multi-faceted installations
  • Allows connection of different module types simplifying inventory considerations
  • Immediate installation feedback for quick commissioning

Specifications

Input OP250-LV OP300-MV/OP400-MV
Rated Input DC power 250 300 / 400 W
Absolute Maximum Input Voltage (Voc) 55 Vdc 75 Vdc
MPPT Operating Range 5 - 55 Vdc 5 - 75 Vdc
Maximum Input Current 10 Adc 10 Adc
Reverse-Polarity Protection Yes
Maximum Efficiency 99.5 %
European Weighted Efficiency 98.8 %
CEC Weighted Efficiency 98.7 %
Inductive Lightning Protection 1 m / ft
Overvoltage Category II
Output During Operation (Power Optimizer connected to operating inverter)
Maximum Output Current 15 Adc
Operating Output Voltage 5 - 60 Vdc
Total Maximum String Voltage (Controlled by Inverter) - US and EU 1-ph 500 Vdc
Total Maximum String Voltage (Controlled by Inverter) - EU 3-ph 950 Vdc
Output During Standby (Power Optimizer Disconnected from Inverter or Inverter off)
Safety Output Voltage per Power Optimizer 1 Vdc
PV System Design
Minimum Number of Power Optimizers per String (1 or More Modules per power optimizer) 8 (1-ph system) / 16 (3-ph system)
Maximum Number of Power Optimizers per String (1 or More Modules per power optimizer) Module power dependent; typically 20 - 25 (1-ph system) / 45 - 50 (3-ph system)
Parallel Strings of Different Lengths or Orientations Yes

Share your knowledge of this product with other customers... Be the first to write a review